Added CycleIgnoreMinimized configuration option settable on Expert page in WPrefs.
When option is set, switch panel cycling ignores minimized (grayed) windows. They
are still visible and can be selected using left/right arrows or mouse click.
The function scaleDownIfNeeded's code is duplicated with the code of
wIconValidateIconSize(), then this function can be removed. The icon
size in the switchpanel should be ~48 pixels, to allow the frame around
the icon. Then, we always should resize the icon to this size. The standard
icon size is specified in WPreferences.icon_size (usually 64 pixels).
The default icon (defIcon) is never used because the function wDefaultGetImage
always returns a icon (it searches the default icon). So we can remove the
defIcon variable, its creation and remove code.
The function create_default_icon sets the panel's default icon. This
is interesting to have a "cache" icon and don't search the default
icon more than one time if the icons don't have icon associated.
The code of create_default_icon was included in the addIconForWindow()
function, this patch only moves it to get a better (clear) code.
memset is the last function call in wmalloc, just before it returns the
newly allocated memory. Therefore it is not needed to call it again
after wmalloc call. Although I would prefer to switch wmalloc to a
calloc-based wcalloc function, the compatibility of WINGs for old apps
should be kept.
The function canReceiveFocus should check if the window is no_focusable first.
If the window is not focusable but is miniaturized, the window is shown in the
switchpanel.
How to reproduce the problem:
- Open an application
- Open the window properties, advanced options
- Set that the application can not get the focus and save
- Test the switchpanel (Alt+Tab) the window doesn't appear
- Minimize the window
- Test the switchpanel (Alt+Tab), the window appears
- If the window is selected (restored), and test again the switchpanel, the window doesn't appear!
Icons in the switchpanel are constrained to the value of the IconSize
preference but the grid in which they are arranged is fixed at 64 pixels.
If IconSize is less than 64x64 the panel will show smaller icons with a
wide spacing, which looks pretty stupid.
Fix it by forcing the switchpanel to attempt to load images at the size
it's going to use. The icon it actually gets may of course still be
smaller.
Some applications running in my machine are only background
windows, e.g.: screenlets showing CPU usage.
In current wmaker version all these applications pollute my
switchpanel, so I wrote this patch (thanks Carlos for the helping me).
It includes an additional advanced option for windows "Do not
include in switchpanel" which, if set, allows applications to
not appear in the switchpanel.
Signed-off-by: Haroldo Santos <haroldo.santos@gmail.com>
If a window has the skip_window_list flag set wmaker currently not only skips
this window from the window list (F11) but also from the switchpanel (TAB).
This patch makes skip_window_list-windows appear in the switchpanel and be
skipped only in the window list, strictly honoring what the name of the flag
is supposed to mean.
The motivation for this is that I have lots of workspaces and almost all of
them has a xterm, so that I set the skip_window_list for the xterms not to
overcrowd the window list. But I still want to alt+TAB to xterms on the current
workspace.
In addition to that, now the "internal window" flag is not checked before
appearing in the switchpanel.
When using Xinerama, make it possible only to cycle between those
windows that are on the currently active head - AFAICT this means
windows that have the majority of their area on the same head as
the pointer.
Patch complete with WPrefs integration, alas this being quite
unusable - for a lack of a better idea, I tucked the option on the
expert panel, making the item list too tall - making it scrollable
would be a nice addition.
The default for the new option (CycleActiveHeadOnly) should be NO,
that is, no change in default behaviour.
For those not familiar with the way Macs cycle windows, the Command-Tab
sequence (Alt-Tab elsewhere) switches between DIFFERENT application windows
and Command-Grave (key above tab) switches between windows owned by the
SAME application as is currently focused. So if you had three Safari and
two Finder windows open, and Safari had focus, Command-Tab would switch to
Finder; Command-Tab would switch back to Safari; Command-Grave would switch
to a different Safari window etc.
This patch implements "something like" the above by only populating the
switchpanel with windows matching the currently-focused WWindow's wm_class
when the new cycling mode is activated. In practice this means you can
switch to The Next XTerm or The Next Firefox Window using this method.
The configuration names for these new shortcuts are GroupNext and
GroupPrev. The patch tells WPrefs.app about them. Of course switching to
The Next Window is still possible with the (unchanged) FocusNext and
FocusPrev keys.
1. Setup two windows in a workspace, one at the center and the
other at a corner. Move the mouse to the center of the screen, so
that the focus goes to the center window. Now, with the help of the
keyboard (with Alt-tab, typically), try and switch the focus to the
other window. In doing so, the switch panel shows up, gives the
focus to the other window and then disappears. However, its
disappearance make it seem to wmaker that the mouse has just
entered the center window, so wmaker gives the focus to that
window again.
2. It is a lit bit more involved. "Raise window when switching
focus with keyboard" needs to be set. In a given workspace, maximize
a first window A, then setup "above" window A two windows B and C
(one in the upper left corner and the other one in the lower right
corner, for example). Move the mouse so as to give the focus to
window B. Press the Alt key, hit the key tab once (window A moves
up to the "top"), then another time (window C is then selected).
Eventually relase the Alt key: window B is given the focus again.
Correction: it is a matter of ignoring some (EnterNotify) events
when the switch panel is active or has just been used.
for arq in `git ls-files *.c`; do
echo $arq;
indent -linux -l115 $arq;
done
The different line break at 115 columns is because
I use a widescreen monitor :-)
This is a small patch to fix an issue with the switchpanel and a large number
of windows which happens only on a Xinerama setup.
When the number of open windows is so large that displaying all of them would
cause the switchpanel to be too wide for the screen, the panel is supposed to
shrink and scroll to accomodate them all.
In Window Maker 0.92.0 this works for single head displays but not for
Xinerama. The panel extends to the next head and gets garbled. This patch fixes
the issue by correctly constraining the panel to the head with the cursor.
Submitted-by: Gilbert Ashley <amigo@ibiblio.org>
small integer and causing unexpected color releases that can crash
Window Maker (Martin Frydl <martin.frydl@systinet.com>)
- fixed a small memory leak in WINGs/wview.c caused by not releasing the
background color of a view (Martin Frydl <martin.frydl@systinet.com>)